WKE03/02 PG 6
SENTINEL II CONTROL SYSTEM
The BREEZAIRE Sentinel II is the precision micro-processor control system that makes the WKE Series the most
sophisticated wine cooling units available. The Sentinel II features a remote display and control panel that serves as a
wine cellar temperature display, programming panel and alarm. The following three parameters are set through the
display-control panel:
1- DESIRED TEMPERATURE OF WINE CELLAR. Choose temperature between 45°F and 65°F.
2- EVAPORATOR FAN OPERATION. Choice of "auto" or "on" modes. Evaporator fan will turn on and off
with the cooling unit in the "auto" mode, and remain on all the time in the "on" mode. The "auto" setting should be
used for normal operation. For floor mount applications where the wine cellar temperature variation is
unacceptable, the "on" setting will work best.
3- ALARM TEMPERATURE. You can choose an alarm temperature between 50°F and 75°F. If the
temperature of the wine cellar goes above the alarm temperature the red alarm indicator on the program panel will
be lit. Choose an alarm temperature approximately 6°F above the desired temperature setting of wine cellar.
The Sentinel II also controls the speed of the condenser fan to provide maximum cooling while reducing energy usage
and noise. During warm days the condenser fan will run at a higher speed than under less severe conditions.
The Sentinel II display-control panel can be mounted directly on the cooling unit face or may be mounted in a remote
location. If a remote location is desired, obtain a standard four wire (two line) telephone extension cord of not more
than 100 feet in length from a local supplier. If the extension cord does not have one female end, an adapter to join the
two male ends will be required.
The Sentinel II is not a temperature sensing device. It is only
a display/control panel so the Sentinel II may be mounted
outside the cellar. The display has three arrows to the far right
of the screen. One arrow, two, or three arrows may be lit at
any time.
SENTINEL II
Alarm light
On
Blinking arrow
Unit is cooling
Arrow lit when
alarm light is on
RED PLUG
CLEAR TUBING
EXTENDED DRAIN TUBE
VIEW
NON EXTENDED DRAIN
(TUBE LOCATION)
GREY
FITTING
Figure 4